Process HVAC & Industrial Refrigeration
Engineered thermal control and process cooling systems built for rigorous industrial runtimes.

Governing Standard
ASHRAE 15 / ISO 5149 / IIAR Standards for Ammonia Refrigeration
Service Overview
Direct installation, mechanical overhaul, and maintenance contracts for industrial chillers, cooling towers, DX split systems, and process air extraction. We manage systems operating 8,760 hours per annum.
Plant Equipment & Systems Covered
- Centrifugal, screw, and scroll chiller plants including primary/secondary pumping
- Ammonia (NH3) and secondary glycol refrigeration for cold storage warehouses
- Industrial Air Handling Units (AHUs), fan coil systems, and ductwork fabrication
- Cooling tower refurbishments, drift eliminator replacement, and water treatment loops
- Dust collection, fume scrubbing, and explosion-resistant industrial exhaust ducting
- Refrigerant leak detection, recovery, and pressure vessel statutory inspections
Standard Execution Procedure
- [1]Heat load modeling and psychrometric analysis for process rooms
- [2]Rigging, setting, and vibration isolation of chillers and condenser units
- [3]Installation of pre-insulated carbon steel and copper refrigerant lines
- [4]Balancing of air volume (TAB) and hydronic flow rates across distribution manifolds
- [5]Preventative maintenance schedules including oil analysis, eddy current tube testing, and belt tensioning
What We Need From You to Quote
Providing these initial parameters allows our estimating engineers to submit a preliminary bill of quantities within 24 hours.
- Process cooling heat load specifications (kW or TR)
- Required chilled water supply and return temperatures
- Chiller plant room dimensions and roof structural loading limits
- Refrigerant type preferences and environmental safety requirements
Speak to a Duty Engineer
Direct telephone line for emergency plant callouts or active breakdown isolation.
+94 11 234 5678Relevant Industry Sectors
Continuous production facilities where equipment downtime directly translates to measurable unit output loss.
Refrigerated logistics hubs and food processing plants where sanitary compliance and thermal containment are mandatory.
Controlled production environments governed by strict particulate limits, pressure cascades, and validated qualification audits.
Adjacent Contracting Services
Process piping, high-pressure steam distribution, condensate return, and pumping systems.
Modular wall systems, HEPA filtration, interlock controls, and pharmaceutical-grade MEP.