Industrial Electrical & Switchgear
Engineered power distribution and automated control infrastructure for continuous manufacturing lines.

Governing Standard
IEC 61439-2 / IEEE Wiring Regulations / National Electrical Code Class 1
Service Overview
Full electrical turnkey execution from transformer secondary terminals down to final sub-distribution boards and machinery disconnects. We fabricate, install, pull cable, terminate, and commission under Class 1 licence requirements.
Plant Equipment & Systems Covered
- Motor Control Centres (MCC) and Variable Speed Drive (VFD) panels
- MV/LV switchgear installation, busbar trunking, and main switchboard retrofits
- Heavy cable tray, ladder racking, and explosion-proof containment (ATEX/IECEx)
- Power factor correction units, harmonic filtration, and surge protection arrays
- Statutory thermal imaging, earth resistance testing, and insulation verification (Megger)
- Uninterruptible Power Supply (UPS) installations and automatic transfer switchgear (ATS)
Standard Execution Procedure
- [1]3-phase power load calculation and distribution layout engineering
- [2]Factory acceptance testing (FAT) and on-site integration of MCC boards
- [3]Pulling and termination of XLPE, SWA, and high-temperature screened cables up to 630mm²
- [4]Lockout-tagout (LOTO) procedures and safe isolation under live plant conditions
- [5]Handover of single-line diagrams, test sheets, and electrical statutory sign-offs
What We Need From You to Quote
Providing these initial parameters allows our estimating engineers to submit a preliminary bill of quantities within 24 hours.
- Existing Single Line Diagram (SLD) or load distribution schedule
- Available transformer capacity and prospective short-circuit fault ratings
- Physical routing drawings or architectural layout of plant rooms
- Target shutdown schedule or permissible work windows (day/night shifts)
Speak to a Duty Engineer
Direct telephone line for emergency plant callouts or active breakdown isolation.
+94 11 234 5678Relevant Industry Sectors
Continuous production facilities where equipment downtime directly translates to measurable unit output loss.
Refrigerated logistics hubs and food processing plants where sanitary compliance and thermal containment are mandatory.
High-density computing and telecommunications infrastructure requiring 100% uninterrupted power and continuous thermal rejection.
Adjacent Contracting Services
Process piping, high-pressure steam distribution, condensate return, and pumping systems.
Critical path planning, multi-trade mobilization, valve overhauls, and plant turnaround execution.